Agree, capillary action does not seem to be referenced or implied in the comic, presenting only the (not "functioning") siphon phenomenon. [[Special:Contributions/172.68.134.142|172.68.134.142]] 16:23, 12 May 2023 (UTC)
 
Agree, capillary action does not seem to be referenced or implied in the comic, presenting only the (not "functioning") siphon phenomenon. [[Special:Contributions/172.68.134.142|172.68.134.142]] 16:23, 12 May 2023 (UTC)
βˆ’
:Seconded/thirded. Capillary action isn't even what they were expecting. The small amount of water in the lower recepticle indicates they correctly ''filled'' the tube, but then as the longer length drained it did not then induce further flow up and over through the shorter length. e.g. nature no longer abhored the resulting vacuum (or there was increased negative-pressure vapourisation, beyond that previously expected, or other method of seepage 'airlock'-breaking) and thus the short-end also drained straight back out again instead of becoming a potentially self-sustaining inflow to the whole siphoning setup.
+
:Seconded/thirded. Capillary action isn't even what they were expecting. The small amount of water in the lowe receptical indicates they correctly ''filled'' the tube, but then as the longer length drained it did not then induce further flow up and over through the shorter length. e.g. nature no longer abhored the resulting vacuum (or there was increased negative-pressure vapourisation, beyond that previously expected, or other method of seepage 'airlock'-breaking) and thus the short-end also drained straight back out again instead of becoming a potentially self-sustaining inflow to the whole siphoning setup.
 
::If the upper end got restricted (say by touching the side of the bucket) the loss of flow would allow air to enter the bottom end and drain out the tube. I've done this. :-( [[User:RIIW - Ponder it|RIIW - Ponder it]] ([[User talk:RIIW - Ponder it|talk]]) 19:07, 12 May 2023 (UTC)
 
::If the upper end got restricted (say by touching the side of the bucket) the loss of flow would allow air to enter the bottom end and drain out the tube. I've done this. :-( [[User:RIIW - Ponder it|RIIW - Ponder it]] ([[User talk:RIIW - Ponder it|talk]]) 19:07, 12 May 2023 (UTC)
 
:::Indeed, even having an especially large diameter "tube" (/pipe etc) can allow air from the bottom to flow up to the peak & break the siphon effect. For reliable results, the lower end needs to be kept immersed or the hose needs to be relatively small in diameter. [[User:ProphetZarquon|ProphetZarquon]] ([[User talk:ProphetZarquon|talk]]) 14:11, 13 May 2023 (UTC)
 
:::Indeed, even having an especially large diameter "tube" (/pipe etc) can allow air from the bottom to flow up to the peak & break the siphon effect. For reliable results, the lower end needs to be kept immersed or the hose needs to be relatively small in diameter. [[User:ProphetZarquon|ProphetZarquon]] ([[User talk:ProphetZarquon|talk]]) 14:11, 13 May 2023 (UTC)

Please note that all contributions to explain xkcd may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see explain xkcd:Copyrights for details). Do not submit copyrighted work without permission!

To protect the wiki against automated edit spam, we kindly ask you to solve the following CAPTCHA:

Cancel | Editing help (opens in new window)

Template used on this page: